pH controller
MIK-PTU200 Turbidity meter
Category: pH controller
Views: 274
Description:
MIK-PTU200 turbidity meter based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of turbidity. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of turbidity value. According to the usage environment, self-cleaning function can be equipped with. It assures the stability of data and reliability of performance; with the built-in self-diagnosis function, it can make sure the accurate data be delivered; besides, the installation and calibration is quite simple.
Download Instructions
Order Hotline: 0086-15158063876
Product Details
Product Description

·Turbidity transmitter

The transmitter can be used to display data measured by the sensor, so the user can get the 4-20mA analog output by transmitter’s interface configuration and calibration. And it can make relay control, digital communications, and other functions a reality. The product is widely used in sewage plant, water plant, water station, surface water, farming, industry and other fields. 


Product 

Turbidity meter

  Model

SUP-PTU200

 Display

128 * 64 dot matrix LCD with LED backlight, 


which can be operated under the direct sunlight

 Power supply

AC:AC220V, 50Hz, 5W;  DC:DC24V

 Output

Three-way analog output 4-20mA, 


Note: the maximum load is 500 ohms

 Relay

Three-way relay can be set up

 Digital 
 communication

MODBUS RS485 communication function,
which can transmit real-time measurements

 Warranty period

1 year

 Material of 
 outside shell

Lower casing:Aluminum with powder covering

cover:PA66+GF25+FR

 Ingress protection

IP65

 Size

145*125*162mm  L*W*H

 Weight

1.3KG



·Turbidity sensor

Product 

Turbidity sensor

 Measure range

0.01-100 NTU 、0.01-4000 NTU

 Indication  resolution

Less than ± 2% of the measured value,


or ± 0.1 NTU Maximax criterion

 Pressure range

≤0.4MPa

 Flow velocity

≤2.5m/s、8.2ft/s

 Environment temp

0~45℃

 Calibration

Sample Calibration, Slope Calibration

 Cable length

Standard 10-Meter Cable, Max Length: 100 Meters

 High voltage baffle

Aviation Connector, Cable Connector

 Main materials

Main Body:SUS316L (Ordinary Version),


Titanium Alloy (Seawater Version)


Upper and Lower Cover: PVC; Cable: PVC

 Ingress protection

IP68

 Weight

1.65 KG



SUP-PTU200 Turbidity Analyzer based on the infrared absorption scattered light method and combined with the application of ISO7027 method, can guarantee the continuous and accurate detection of turbidity. Based on ISO7027, infrared double scattering light technology will not be affected by chroma for the measurement of turbidity value. According to the usage environment, self-cleaning function can be equipped with. It assures the stability of data and reliability of performance; with the built-in self-diagnosis function, it can make sure the accurate data be delivered; besides, the installation and calibration is quite simple.


1584345472797464.jpg


1584345640667681.jpg

1584345640690660.jpg

1584345640124026.jpg

1584344869687131.jpg

1584344869568019.jpg

1584344869101589.jpg

1584344869101589.jpg


Contact Online
Hotline